Article No. VK-10400

Ultrasonic echoscope GS200

High-resolution ultrasonic measurement system for ultrasonic measurements using single-element transducers,
Delivery includes manual, power cable, USB cable, software

Article No. VK-10410

Ultrasonic Echoscope GS200i

High-resolution ultrasonic measurement system based on the GS200 (article no. 10400) extended by an imaging module for ultrasonic measurements using single-element transducers and an ultrasonic array transducer, delivery includes ultrasonic array transducer, manual, power cable, USB cable, software

Article No. VK-10420

Ultrasound Test Phantom

Tissue-equivalent phantom including test structures for quality assurance and evaluation of the accuracy and performance of ultrasonic imaging systems

Article No. VK-10430

Ultrasound Fetal Phantom

Tissue-equivalent phantom including a fetus model for teaching basics of sonographic fetometrics and training of determining fetometric variables

Article No. VK-10224

Ultrasound Breast Model with Cysts

Realistic breast model with two fluid-filled, non-palpable cysts to carry out experiments on the subject of medical diagnostics (breast tumor diagnosis).For educational purposes only.

Article No. VK-50400

Ultrasonic Doppler FlowDop200

Ultrasonic device for carrying out experiments on the subject of Doppler effect, fluid mechanics and Doppler sonography in vascular diagnostics, Delivery includes manual, power cable, USB cable, software

Article No. VK-50151

Flow Pipe 1/2“

Acrylic pipe with inside diameter of 16 mm and connections for 1/2" tubes as component of a flow circuit for the investigation of flow phenomena

Article No. VK-50152

Flow Pipe 3/8“

Acrylic pipe with inside diameter of 10 mm and connections for 3/8" tubes as component of a flow circuit for the investigation of flow phenomena

Article No. VK-50153

Flow Pipe 1/4“

Acrylic pipe with inside diameter of 7 mm and connections for 1/4" tubes as component of a flow circuit for the investigation of flow phenomena

Article No. VK-16100

EchoSet

Compact ultrasonic measurement system with single-element ultrasonic transducer and various testing objects for exploring basic phenomena of ultrasound physics and their technical use in medicine and industry

Article No. VK-16400

ImageSet

Compact ultrasonic measurement system with an ultrasonic array transducer and ImagePhantom for exploring how a ultrasonic B-Image is generated using the B-Mode-Imaging method as well as teaching basics of sonographic fetometrics

Article No. VK-76000

Acoustic Absorber

to prevent reflections and standing wavesimpedance matching to water (1.5 MRayl), loss < 20 dB/cm; area 228 x 228 mm

Article No. VK-75000

Water tank

For sound field measurements with stable glass walls for easy cleaning, size 58 x 45 x 30 cm

Article No. VK-IND08

IND08 Detection of discontinuities

Analysis of applicability and performance of different discontinuity locating techniques of non-destructive testing with ultraound using a test block with different types of discontinuities (defects)

Article No. VK-MED05

MED05 Vascular Ultrasound (Angiology)

Demonstration of blood flow examinations by means of the ultrasonic Doppler method using a realistic arm phantom, Presentation of the differences between continuous venous and pulsatile arterial flow

Article No. VK-MED07

MED07 Ultrasound test phantom

Examination of an ultrasound test phantom with a normal beam probe and/or an array probe. Assessment of accuracy and performance of the ultrasound system in terms of resolution, dead zone and further parameters

Article No. VK-PHY05

PHY05 Spectral investigations

Demonstration of the difference between the spectrum of a pulse and the spectra of periodic signals using the simple model of multiple reflection at a plate

Article No. VK-PHY07

PHY07 Shear waves in solids

Investigation of the formation and propagation of longitudinal and shear acoustic waves in solids based upon the ultrasonic transmission through a plane parallel plate at different angles of incidence

Article No. VK-PHY08

PHY08 Ultrasonic B-Scan

Demonstration of the basics of the B-scan method by recording the ultrasonic cross-sectional image of a simple test object "by hand" using an ultrasonic echoscope

Article No. VK-PHY20

PHY20 Determination of focus zone

Characterization of the sound fields of two ultrasonic probes of different frequencies by scanning reflection and transmission with a hydrophone (near field length, focus zone, axial resolution power)

Article No. VK-60200

CT Scanner for GS200/GS200i

Scanner system with sample holder and two step motors with exact angle positioning necessary for the rotation and linear shifting of the test sample to carry out experiments on the subject of computer tomography using ultrasound, Delivery includes CT sample holder (article no. 60124)

Article No. VK-60120

CT Reservoir

Acrylic measuring reservoir for CT scanner (article no. 60200) with built-in support for several ultrasonic transducers, dimensions: 430 mm x 150 mm x 150 mm

Article No. VK-60121

CT Sample

Test cylinder made of black opaque plastic with built-in structures of different absorption and sound velocity distributions to carry out experiments on the subject of ultrasonic tomography

Article No. VK-10201

Test Block (transparent)

Test block made of homogeneous, transparent acrylic including several groups of differently sized defects for teaching basics of echoscopic investigationsod

Article No. VK-10204

Test Block (black)

Test block made of black opaque acrylic including several groups of differently sized defects for localization of non-visible defects

Article No. VK-10218

Shear Wave Set

Acrylic and aluminium samples with holder and sample reservoir for measuring angle-dependent transition from longitudinal to shear waves

Article No. VK-50150

Standpipe

Pressure scale with four standpipes, tubes and connectors for integration into the flow circuit (article no. 50201) for the investigation of flow laws

Article No. VK-10220

Heart Model

Double container with movable membrane for simulation of cardiac wall and heart valves movements, suitable for examinations using the TM mode

Article No. VK-50201

Flow Measuring Set

Set including flow pipes with three different inside diameters, according Doppler prisms, tubes and connectors for the investigation of flow phenomena

Article No. VK-10222

Eye Phantom

Enlarged eye phantom to carry out experiments on the subject of medical diagnostics (ophthalmology).For educational purposes only.

Article No. VK-20100

CW Generator SC600

Ultrasonic generator for producing continuous high-powered ultrasonic waves over a wide frequency range of up to 20 MHz

Article No. VK-10233

Angle Beam Wedges 17°

Acrylic delay line with incidence angle to carry out experiments on the subject of non-destructive testing (angle beam testing)

Article No. VK-10234

Angle Beam Wedges 38°

Acrylic delay line with incidence angle to carry out experiments on the subject of non-destructive testing (angle beam testing)

Article No. VK-10235

Angle Beam Wedges 56°

Acrylic delay line with incidence angle to carry out experiments on the subject of non-destructive testing (angle beam testing)

Article No. VK-10242

Discontinuity Test Block

Aluminium test block with different reflector types for locating of discontinuities using techniques such as the echo, delta, tandem, transfer and angle techniques

Article No. VK-10351

Hydrophone Set for Echoscope (BNC)

Set including a hydrophone for connection to an echoscope, holders and sample reservoir to carry out experiments investigating ultrasound propagation phenomena and sound fields

Article No. VK-10300

Lamb Wave Set

Set including various Lamb wave combinations for investigating the frequency-dependent propagation velocity of ultrasonic waves in a thin glass plate (Lamb waves)

Article No. VK-10310

Tripod Set

Set including tripod, two solid bossheads and two universal clamps made of hard aluminium suitable for all holdings necessary for GAMPT experiments

Article No. VK-20200

Debye-Sears-Set

Sample reservoir with adjustments, ultrasonic multifrequency probe and laser module for exact positioning of the components for the generation of standing waves during the Debye-Sears experiment

Article No. VK-20211

Laser Module (green)

Green laser module with a wavelength of approx. 532 nm for connection to the cw ultrasonic generator SC600 (article no. 20100)

Article No. VK-20225

AOM Sample Reservoir

Sample reservoir made of glass with fixed laser and lens support offers optimal conditions for sound reflection for the production of standing waves and radiography with laser light, suitable for all liquids

Article No. VK-20230

Projection Lens

Plano-convex optical lens for experiments to produce a divergent laser beam, lens diameter: 12.5 mm

Article No. VK-20227

Acoustic Absorber

Absorbermat made of special silicone material for the prevention of undesired sound reflections in the AOM experiments or when using the thermoacoustic sensor, dimensions: 110 mm x 90 mm